Electroplating and Electroless Coatings

Leading Manufacturers, Exporters, Wholesaler, Retailer, Importer of Fischerscope X-Ray XDL Series XDL Electroplating and Electroless Coatings, XDV-SDD Electroplating and Electroless Coatings and XDV-U Electroplating and Electroless Coatings from Pune.

Business Type Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Importer
Repeatability Greater than 1 % for gold,measurement time 60 sec
Brand Fischer
Power Type Electric
Operation Mode Automatic
Dimension 403 x 588 x 365 mm
Power Supply AC 230 V 50 / 60 Hz

Preferred Buyer From

Location Anywhere in India

FISCHERSCOPE X-RAY XDL X-ray fluorescence measuring device for manual as well as automated coating thickness measurements on decorative and protective coatings. They are universally applicable energy dispersive X-ray measuring instruments used for non-destructive thickness measurements as well as analysis of thin coatings for the measurements on mass-produced parts as well as printed circuit boards. FISCHERSCOPE X-RAY XDL is designed under the direction of practiced quality controllers following the international industrial standards. 

 

Models

 

  • XDL 210: Plane support stage, fixed Z-axis

  • XDL 220: Plane support stage, motor-driven Z-axis

  • XDL 230: Manually operable XY-stage, motor-driven Z-axis

  • XDL 240: Motor-driven XY-stage that moves into the loading position automatically, when the protective hood is opened. Motor-driven programmable Z-axis

 

Applications

 

  • Measurement of electroplated mass-produced parts

  • Study of thin coatings like decorative chromium-plating

  • Examination of functional coatings in the electronics as well as semiconductor industries

  • Automated measurements such as printed circuit boards

  • Solution study in the electroplating

Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Importer
Recommended DFT 70 +/-5 Microns per coat
Covering Capacity 90-120 Sq. ft./ ltr/ 2 coats at 35 micron DFT
Grinding +7 on Hegmen Gauge
Specific Gravity 1.35 +/- 0.1 kg/ltr.
Method of Application Brush / Spray/ Roller
Recommended Thinner SP-C.R Thinner

Preferred Buyer From

Location Anywhere in India

The instrument of Electroplating Thickness ensures quick and exact materials analysis with user-friendly features. The array is ideal for the analysis of varied precious metal as well as gold alloys. The collection comes with geometric arrangement of hardware components. X-ray source as well as detector is situated below the measurement chamber and the measurement is conducted from bottom to top for easy & swift positioning of the samples. The range comes in varied versions only differ in terms of detectors, number of apertures, X-ray tubes, and filters.

Features

  • X-ray tube with W-anode as well as glass window or micro-focus X-ray tube having W-anode and beryllium window.
  • Maximum operating conditions: 50 kV, 50W
  • Proportional counter tube, Silicon drift detector as X-ray detector or silicon PIN diode
  • Aperture: fixed or 4-x automatically exchangeable,  0.2 mm to  2 mm
  • Primary filter: fixed, 3-x exchangeable or 6-x automatically exchangeable
  • Fixed sample support
  • Video camera for optical observations of the measurement position along the axis of the primary X-ray beam. Crosshairs with calibrated scale (ruler) as well as display of the measurement spot Design-approved, completely protected instrument compliant with the German X-ray ordinance.


Applications

  • Gold as well as precious metal study in the Jewellery and watch industries
  • Measurement of thin coatings of few nanometers like Au and Pd on the printed circuit boards as well as electronics components
  • Trace study (e.g. harmful substances in electronic components (ROHS) or tools)
  • Examination of light elements like Al, Si, P with the XAN 250
  • General materials analysis as well as coating thickness measurement in testing institutions, laboratories and universities
Read More...


Yes! I am interested


Business Type Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Importer
Element Range Aluminum Al (13) to Uranium U (92) up to 24 elements simultaneously
Zoom Factor Up to 1080x (Optical: 30x, 90x, 270x; Digital: 1x, 2x, 3x, 4x)
X-ray Detector Proportional Counter Tube
Absorber XULM 240 only: optional cobalt or nickel absorber
High Voltage Three steps: 10 kV, 30 kV, 50 kV

Preferred Buyer From

Location Anywhere in India

Coating thickness gauge for electroplating and electroless coatings XDV-µ or X-Ray Fluorescence Tester is available in various technical specifications. These are widely used for non-destructive analyses and measurements of coating thickness on very small components and structures, even with complex coating systems.

Applications

  • Measurements on very small flat components and structures such as printed circuit boards, contacts or lead frames
  • Analysis of very thin coatings, e.g., gold/palladium coatings of ≤ 0.1 μm (0.004 mils)
  • Measurement of functional coatings in the electronics and semiconductor industries
  • Determination of complex multi-coating systems
  • Automated measurements, e.g., in quality control
Read More...