Goldscope SD 515 SD 515 Gold Testing Machine For Jewellery Retail Stores

Goldscope SD 515 SD 515 Gold Testing Machine For Jewellery Retail Stores
Business Type Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Importer
Usage/Application Industrial
Model Number/Name SD 510
Analysis Elements Silver, Platinum, Copper, Gold
Click to view more

Preferred Buyer From

Location Anywhere in India

Product Details

Operation Mode
Automatic
Power Type
Electric
Automation Grade
Automatic
Accuracy
0.01
Dimension
403 x 588 x 365 mm
Brand
Fischer
Power Supply
AC 230 V 50 / 60 Hz

The X-ray fluorescence measuring instruments of the GOLDSCOPE series are optimized for fast, cost-effective and non-destructive analysis of jewelry, coins and precious metals. Furthermore, the instruments are well suited for determining the thickness of gold coatings on sterling silver and rhodium coatings on gold alloys. The GOLDSCOPE series comprises four different instruments to fulfill the specific demands from the fast purchase and sale of gold up to the high-precision analysis of precious metals.

 

Typical fields of application are the analysis of

  • Jewelry, precious metals
  • Yellow and white gold
  • Platinum and silver
  • Rhodium
  • Alloys and coatings

Outstanding accuracy and long-term stability are characteristics of all X-RAY systems from FISCHER. The necessity of recalibration is considerably reduced, saving time and effort. The GOLDSCOPE SD 510 is equipped with a modern silicon PIN detector, which achieves high accuracy and good detection sensitivity. The fundamental parameter method by FISCHER allows for the analysis without calibration.

 

Design

  • The GOLDSCOPE instruments are designed as user-friendly bench-top instruments. Due to their compact design, the instruments are lightweight and require only a little space.
  • For the smallest footprint, the measurement chamber door of the GOLDSCOPE SD 510 does not open upwards, but towards the front. Thus, you can place a notebook for operation onto the instrument, which saves even more space.
  • For quick and easy sample positioning, the X-ray source and detector assembly is located in the instrument“s lower chamber. The measuring direction is from underneath the sample, which is supported by a transparent window.
  • The integrated video-microscope with zoom and crosshairs simplifies sample placement and allows for a precise measuring spot adjustment.
  • The entire operation and evaluation of measurements as well as the clear presentation of measurement data is performed on a PC, using the powerful and user-friendly WinFT software.
  • All GOLDSCOPE instruments fulfill DIN ISO 3497 and ASTM B 568.

 

Application

  • Recommended area application: of Retail shops, Banks and Gold Lending, Gold Exchange, Personal Use

 

General Specification

  • Intended use: Energy dispersive X-ray measuring instrument (EDXRF) to analyze precious metals
  • Repeatability:1%for gold, measurement time 60 sec
  • Design: GOLDSCOPE SD: Bench top unit with towards the front opening hood.
  • Measuring direction: Bottom up

 

Electrical Data

  • Power supply and consumption: AC 115 or 230 V, 50/60 Hz, max. 120 W without evaluation PC
  • Protection class : IP40

 

Environmental Conditions

  • Operating temperature :10DegreeC to 45DegreeC/ 50DegreeF to 113DegreeF
  • Storage/Transport temperature: -20DegreeC to 80DegreeC /-4DegreeF to 176DegreeF
  • Relative humidity:95%

 

Sample Alignment

  • Sample positioning: Manually
  • Video microscope: High-resolution CCD colour camera for optical monitoring of the measurement location along the primary beam axis, Crosshairs with a calibrated scale (ruler) and spot-indicator, Adjustable LED illumination
  • Zoom factor: Digital 1x, 2x, 3x, 4x

 

Evaluation Unit

  • Computer: Windows-PC
  • Software : WinFTM optimized for GOLDSCOPE Including Gold Setup, Jewelry Setup and Fashion Jewelry Setup

 

Standards

  • CE approval: EN 61010
  • X-Ray standards: DIN ISO 3497 and ASTM B 568
  • Approval: Individual acceptance inspection as a fully protected instrument according to the German regulations Deutsche Rontgenverordnung-RoV

 

Sample Stage

  • Design: Fixed sample support
  • Max. sample weight [kg/lb]: 13/29
  • Usable sample placement area : 305 x 490/ [mm/in] 12 x 19.3
  • Max. sample height [mm/in]: 130/5.1

 

Dimensions

  • External dimensions: 405 x 588 x 426/
  • Width x depth x height [mm/in]: 16 x 23 x 17
  • Weight [kg/lb]: approx. 45/99 X-Ray Source
  • X-ray tube :Tungsten tube, thermally stabilized
  • High voltage, three steps [kV]: 30, 40, 50
  • Primary filter, Material and thickness : none
  • Aperture (Collimator) :fixed [mm/mils] 1.0/39

 

X-Ray Detection

  • Detector type :Silicon PIN detector peltier-cooled
  • Resolution fwhm for Mn-ka[eV]:180
  • Element range: S (16) to U (92)
  • Measuring distance [mm/in]: 0to25/0to1,Distance compensation with patented DCM method for simplified measure- ments at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary.

 

Order

  • Order number :605-684 incl. Gold Setup, Jewelry Setup and Fashion Jewelry Setup
  • Factory Calibration: 605-692 Special GOLDSCOPE product modification and technical consultation on request

Yes! I am interested

Looking for "Goldscope SD 515 SD 515 Gold Testing Machine For Jewellery Retail Stores" ?


Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us