Gold testing machine in hallmarking centres: XAN-FD is a fast and non-destructive coating thickness measurement and material analysis. These are compact in size and widely applicable as an energy-dispersive X-ray fluorescence measuring instrument.

Our machines are extensively used for non-destructive thickness measurements and material analysis. These are fitted with electrically changeable apertures and primary filters and modern silicon PIN detector for excellent detection sensitivity and high accuracy. These can be used for coating systems as well as solid and liquid Samples can be analyzed standard-free. Besides, these can easily measure up to 24 elements in a Range from aluminum (13) to uranium (92) simultaneously.

Our machines are acclaimed for their long term stability, excellent accuracy, long term stability and ergonomic design. These are very easy to operate and acclaimed for fast calculation and quick data presentation. These are well suited for measuring and analyzing thin coatings, even with very complex compositions or small concentrations.

Design
  • We provide user friendly bench-top instruments. These are available in two different range including XAN-FD and XAN 152 and these differ in support stage and the housing size
  • These are ideal to measure range of up to 22 mm. straightened with the integrated video-microscope with crosshairs and up to 184x zoom factor simplifies sample placement, these devices are very easy to install, operate and maintain
  • These are operated through powerful WinFTM® 2 FISCHERSCOPE® X-RAY XAN®-FD, XAN® 152 -FD, XAN® XAN® 152 software, which make these very user friendly and easy to use.

 

Typical areas of application are
  • Measurement of functional coatings in the electronics and semiconductor industries
  • Analysis of alloys in the jewellery and watch industries
  • Research in universities and in the industries

 

General Specifications

  • Intended use Energy dispersive X-ray fluorescence measuring instrument (EDXRF) to determine thin coatings and alloys
  • Element range Aluminum (13) to Uranium (92), up to 24 elements simultaneously
  • Design Bench-top unit with hood opening upwards
  • Measuring direction Bottom-up method 

 

X-ray source
  • X-Ray tube Micro focus tungsten tube with beryllium window
  • High voltage Three steps 10 kV, 30 kV, 50 kV
  • Aperture (collimator) 4x changeable: 0.2 mm, 0.6 mm, 1 mm, 2 mm, others on request
  • Primary filter 3x changeable: Nickel, Aluminum, free, others on request
  • Measurement spot Depending on the measuring distance and on the aperture in use; the actual
  • measurement spot size is shown in the video image.
  • Smallest measurement spot: approx. 0.3 mm
  • Measuring distance 0 20 mm (0 0.8 in)
  • Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications an additional calibration might be necessary.

 

X-ray detection

X-ray detector Silicon PIN detector with peltier cooling and Resolution 180 eV (fwhm at Mn-K±)

Sample orientation
  • Video microscope:High-resolution CCD color camera for optical monitoring of the measurement
  • location along the primary beam axis,Crosshairs with a calibrated scale (ruler)
  • and spot-indicator,Adjustable LED illumination of the measurement location
  • Zoom factor:34x ... 184x (optical: 34x46x; digital: 1x, 2x, 3x, 4x)
Read More...


Yes! I am interested


Business Type : Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Importer

Product Details

Protection Class IP40
Brand Fischer
Usage/Application Industrial
Analysis Elements Gused, Silver,Platinum,Copper
I deal in New Only
Power Type Electric
Operation Mode Automatic
Accuracy 0.05
Suitable Testing and Tunch Centre
Dimension 403 x 588 x 365 mm
Detector SI PIN
Standard Conformity IS 710-1976

Preferred Buyer From

Location Anywhere in India

GOLDSCOPE SD 515 is exceptionally designed entry-level X-ray fluorescence measurement instrument used for fast as well as non-destructive analysis along with coating thickness measurement of different metals like gold, silver alloys. The Gold Testing Machine GOLDSCOPE SD 515 is also ideal during non-destructive analysis of coins, jewellery, and precious metals. They are highly useful for the study of precious metals as well as their alloys for composition and coating thickness up to 24 elements in the variety of chlorine (17) to uranium (92).

Our range of machine in assaying centers: GOLDSCOPE SD 515  is widely acclaimed for exceptional accuracy and high stability. They are acknowledged for the time-saving property as well as longer service life. Fitted with modern silicon PIN detector, the machines ensure high accuracy and excellent detection sensitivity.

Features
Excellent accuracy in the analysis as well as coating thickness measurement
Reduces the recalibration requirements to save time and effort
Available with PIN detector for high precision
Most advantageous detection sensitivity

Application Areas

  • Alloys and coatings
  • Dental alloys
  • Jewellery
  • Multi layer coatings
  • Platinum and silver
  • Precious metals
  • Rhodium
  • Yellow and white gold


General Specification

  • Intended use: Energy dispersive X-ray measuring instrument (EDXRF) to analyze precious metals and their alloys in composition and coating thickness.
  • Element range:Chlorine (17) to Uranium (92) up to 24 elements simultaneously
  • Repeatability: 1 for gold, measurement time 60 sec
  • Design: Bench top unit with towards the front opening hood
  • Measuring direction:Bottom up


X-Ray Source

  • X-ray tubeTungsten tube, thermally stabilized
  • High voltage Three steps: 30 kV, 40 kV, 50 kV
  • Aperture (Collimator): 1 mm (39 mils), optional  2 mm (79 mils)
  • Measurement spot:Aperture diameter plus 200 ¼m (8 mils),at measurement distance MD= 0mm


X-Ray Detection

  • X-ray detectorSilicon PIN detector with peltier cooling
  • Resolution (fwhm for Mn-K±) 180 eV
  • Measuring distance 25 mm (01 in)
  • Distance compensation with patented DCM method for simplified
  • measurements at varying distances. For particular applications or for
  • higher demands on accuracy anadditional calibration might be necessary.


Sample Alignment

  • DesignFixed sample support
  • Usable sample 310 x 320 mm (12.2 x 12.6 in)
  • placement area
  • Max. sample weight 13 kg (29 lb)
  • Max. sample height 90 mm (3.5 in)


Electrical Data

  • Power supply AC 115 V or AC 230 V 50 / 60 Hz
  • Power consumptionmax. 120 W, without evaluation PC
  • Protection class IP40


Dimensions

  • External dimensions Width x depth x height [mm]: 403 x 588 x 365 mm, [in]: 15.9 x 23.1 x 14.4
  • Weight Approx. 45 Kg (99 lb)


Environmental Conditions

  • Operating temperature 10°C - 40°C / 50°F- 104°F
  • Storage/Transport temperature 0°C - 50°C / 32°F- 122°F
  • Admissible air humidity95 %, non-condensing
  • Evaluation Unit
  • ComputerWindows-PC
  • Software Standard: Fischer WinFTM BASIC including PDM
  • Optional: Fischer WinFTM SUPER


Standards

  • CE approval EN 61010
  • X-Ray standards DIN ISO 3497 and ASTM B 568
  • ApprovalFully protected instrument with type approval according to the
  • German regulations "Deutsche Rntgenverordnung-R.
Read More...


Yes! I am interested


Business Type : Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Importer


Details 01

Application

Analysis of

  • Jewellery, precious metals and dental alloys Yellow and white gold
  • Used in Gold Manufacturing, Assaying and Refinery.
  • Platinum and silver
  • Rhodium
  • Alloys and coatings
  • Multi layer coatings

Design

Fixed Sample Support

For quick and easy sample positioning, the X-ray source and semiconductor detector assembly is located in the instruments lower chamber. The measuring direction is from underneath the sample, which is supported by a transparent window. The integrated video-microscope with zoom and crosshairs simplifies sample placement and allows precise measuring spot adjustment.

General Specification

Intended use

Energy dispersive X-ray measuring instrument (EDXRF) to analyze Gold, precious metals and their alloys in composition and coating thickness.

Element range

Chlorine (17) to Uranium (92) up to 24 elements simultaneously

Repeatability

0.5 ° for gold

Measurement time

60 sec

Design

Bench top unit with upwards opening hood

Measuring direction

Bottom up

X-Ray Source

X-ray tube

Micro-focus tungsten tube with beryllium window

Aperture (Collimator)

1 mm (39 mils), optional 2 mm (79 mils) or 0.6 mm (23.6 mils)

Measurement spot

Aperture diameter plus 200 m (8 mils), at measurement distance MD = 0 mm

 

 

X-Ray Detection

X-ray detector

Silicon Drift Detector (SDD), peltier-cooled Resolution (fwhm for Mn-K±) 160 eV

Measuring distance

0....10 mm (0...0.4 in)

Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary

Dimensions

External dimensions

Width x depth x height 403 x 588 x 365 mm (16 x 23.2 x 14.4 in)

Weight

Approx. 45 kg (99 lb)


Details 02

XAN-220 XAN-222
CE approval EN 61010 EN 61010
X-Ray standards DIN ISO 3497 and ASTM B 568 DIN ISO 3497 and ASTM B 568
Approval Fully protected instrument with type approval according to the German regulations "Deutsche Rntgenverordnung-RöV". Individual acceptance inspection as a fully protected instrument according to the German regulations "Deutsche Rntgenverordnung-RV".

Preferred Buyer From

Location Anywhere in India

Gold testing machine in assaying centres: XAN220 is available in various technical specifications these are widely used for fast and non-destructive analysis and coating thickness measurement of gold and silver alloys. These are optimized X-ray fluorescence measuring instruments, acclaimed for compact size and consistent performance.

These are widely used for the analysis of precious metals and their alloys in composition and coating thickness and used for the measurement of up to 24 elements in the range of chlorine (17) to uranium (92). Our products are extensively acclaimed for its excellent accuracy and long term stability.

These are admired for high functional efficiency, time saving quality and effective usage. Owing to its good detection sensitivity and high accuracy, these are widely recommended by large numbers of clients.

Environmental Conditions

  • Temperature: Operation 10°C 40°C / 50°F 104°F
  • Temperature Storage/Transport :0°C 50°C / 32 F 122°F
  • Admissible air humidity 95 %, non-condensing


Evaluation Unit

  • Computer Windows®-PC
  • Software Standard: Fischer WinFTM® BASIC including PDM®
  • Optional: Fischer WinFTM® SUPER
Read More...


Yes! I am interested


Business Type : Manufacturer, Exporter, Supplier, Retailer, Wholesaler, Importer


Details 01

Application

  • Gold Purity Testing
  • Gold Coating Thickness
  • Gold analysis in manufacturing, refinery and Hallmarking centres.
  • Measurement of functional coatings, starting from a few nanometers, in the electronics and semiconductor industries
  • Trace analysis for consumer protection, e.g. lead content in toys
  • Analysis of alloys with highest requirements of accuracy in the jewellery and watch industries and in metal refineries
  • Research in universities and in the industries

 

 

 

Design

  • These are available in two different range including XAN 250 and XAN 252.
  • These are user friendly devices acclaimed for compact size and consistent performance.
  • Our devices are acclaimed for their quick and easy sample positioning and consistent performance.
  • These are fitted with the X-ray source and semiconductor detector which are further located in the instrument‘s lower chamber.
  • Engineered under the firm direction of experienced quality controllers, these are fitted with the integrated video-microscope with zoom and crosshairs simplifies sample placement which further allows precise measuring spot adjustment and ensure clear presentation of measurement data on a PC with the help of powerful and user-friendly WinFTM® software.
  • These are designed and developed in accordance with German regulations "Deutsche Rontgenverordnung-rov".

 

 

 

 

Specification

Intended use

Energy dispersive x-ray fluorescence measuring instrument (EDXRF) to determine thin coatings, Gold Testing, Gold analysis, trace elements and alloys

Element range

Aluminium (13) to Uranium (92) up to 24 elements simultaneously

Design

Bench top unit with upwards opening hood

Measuring direction

Bottom up

 

 

 

X- Ray Source

X-ray tube

Micro-focus tungsten tube with beryllium window

Aperture (Collimator)

4x changeable: 0.2 mm (7.9 mils), 0.6 mm (23.6 mils), 1 mm (39.4 mils), 2 mm (78.7 mils), others on request

Primary filter

6x changeable: Ni, free, Al 1000 m (39.4 mils); Al 500 m (19.7 mils); Al 100 m (3.9 mils); Mylar 100 m (3.9mils)

Measurement spot

Depending on the measuring distance and on the aperture, the actual measurement spot size is shown in the video image. Smallest measurement spot: approx. 0.3 mm (11.8 mils)

 

 

 

X-Ray Detection

X-ray detector

Silicon Drift Detector (SDD), peltier-cooled Resolution (fwhm for Mn-K±) 160 eV

Measuring distance

0....10 mm (0...0.4 in)  Distance compensation with patented DCM method for simplified measurements at varying distances. For particular applications or for higher demands on accuracy an additional calibration might be necessary.

 

 

 

 

Sample Stage

Design

Fixed sample support

Usable sample placement area

310 x 320 mm (12.2 x 12.6 in)

Max. sample weight

13 kg (29 lb)

Max. sample height

90 mm (3.5 in)

 

 

Dimensions

External dimensions Width x depth x height

403 x 588 x 365 mm (16 x 23.2 x 14.4 in)

Weight Approx.

45 kg (99 lb)


Details 02

Standards XAN 250 XAN 252
CE approval EN 61010 EN 61010
X-Ray standards DIN ISO 3497 and ASTM B 568 DIN ISO 3497 and ASTM B 568
Approval Fully protected instrument with type approval according to the German regulations "Deutsche Rontgenverordnung-RoV". Individual acceptance inspection as a fully protected instrument according to the German regulations "Deutsche Rontgenverordnung-Ro

Download


Preferred Buyer From

Location Anywhere in India

The high-end measurement system Fischerscope X-Ray XAN 250 was developed specifically for high-precision analysis of precious metals as required for Hallmarking and assay offices. Gold testing machine in assaying centres: XAN250 is engineered using best available techniques. These are high performance X-ray fluorescence measuring instruments widely used for fast and non-destructive material analysis and coating thickness measurement. Compact sized these devices are acclaimed for high performance, longer service life and accurate measurement.

Environmental Conditions

  • Temperature Operation:10°C 40°C / 50°F 104°F
  • Temperature Storage/Transport: 0°C 50°C / 32°F 122°F
  • Admissible air humidity:95 %, non-condensing


Evaluation Unit

  • Computer:Windows®-PC
  • Software:Standard: Fischer WinFTM® BASIC including PDM®
  • Optional: Fischer WinFTM® SUPER
Read More...